1、 Instrument Overview:
Single cable conductor vertical combustion testing machineObtaining and determining the ability parameters of a single electrical wire or cable on an electric bicycle to prevent flame spread under laying conditions. Evaluate all electrical wires with a nominal cross-sectional area ≥ 0.5mm2 and conduct tests according to the methods specified in GB18380.12; For all electrical wires with a nominal cross-sectional area<0.5mm2, the flame propagation performance test on the surface of a single cable shall be evaluated according to the method specified in GB18380.22. The equipment can select the ignition time based on the specifications of the sample, and evaluate the experimental results according to the judgment requirements after the ignition is completed.
2、 Compliant with standards:
GB17761-2024 "Safety Technical Specification for Electric Bicycles";
GB/T18380.11-2022 "Combustion tests for cables and optical cables under flame conditions - Part 11: Test apparatus for vertical flame propagation of single insulated wires and cables";
GB/T 18380.12-2022 "Combustion tests for cables and optical cables under flame conditions - Part 12: Vertical flame propagation test for single insulated wires and cables -1kW premixed flame test method";
GB/T 18380.22-2008 "Burning test for cables and optical cables under flame conditions - Part 22: Vertical flame propagation test for single insulated thin wire cables - Diffusion flame test method".
IIISingle cable conductor vertical combustion testing machineMain technical parameters:
1. Maximum size of vertical combustion box body: W400xH1300xD450mm;
2. Burning gas: high-purity propane gas or high-purity liquefied gas (to be provided by the user) is used;
3. Sample length: 600 ± 25mm;
4. Sample area: conductor diameter greater than 0.8mm or total cross-sectional area greater than 0.5mm2;
5. Test environment: This device must be able to be placed in an environment without wind and with a temperature of (23 ± 10) ℃ for testing;
6. Ignition method: electronic high-voltage ignition;
7. Fire supply time: 0.1-999.9S can be set arbitrarily, and the flame can continuously burn the sample within the set time;
8. Delayed ignition timing: continuous timing from 0.1 to 999.9 seconds, with pause function;
9. Control method: PLC+touch screen control is adopted, and the test combustion time is set on the screen. During flame temperature calibration, the combustion time can be controlled and the temperature value can be displayed;
10. Gas flow range: 0.1-1L/min;
11. Air flow range: 0.1-1m3/h;
12. Combustion burner:
12.1 The standard power is 1KW, the blue flame core height is 50-60mm, and the total flame height is 170-190mm, which meets the requirements of GB/T5169.14-2007 and IEC60695-11-2:2003 standards;
When the blowtorch is in a vertical position and the air inlet is closed, the blowtorch produces a bright flame. Adjust the gas flow rate to make the total length of the bright flame 125 ± 25mm;
13. Equipment power supply: AC 220V, 50/60Hz, 2A.