Oxygen Monitor - AII GPR-1500 GB/2500 GB

NegotiableUpdate on 01/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Oxygen Monitor - AII GPR-1500 GB/2500 GB Features Measurement Range from 0-10ppm up to 0-25% O2 Accuracy 2% better than range Sensor Life 24 months (under normal conditions) 4-20 mA Output 18-24V Loop Powered XLT Sensor can be used for CO2 background gas
Product Details

Oxygen Monitor - AII GPR-1500 GB/2500 GB


Oxygen Monitor - AII GPR-1500 GB/2500 GB Features Measurement Range from 0-10ppm up to 0-25% O2 Accuracy 2% better than range Sensor Life 24 months (under normal conditions) 4-20 mA Output 18-24V Loop Powered XLT Sensor can be used for CO2 background gas




Oxygen Monitor - AII GPR-1500 GB/2500 GB

This oxygen transmitter is particularly suitable for measuring oxygen inside glove boxes, ranging from air levels (21% oxygen content) to ppm levels (0-10 ppm oxygen content). It is easy to install and matches the needs of glove box operators. The analyzer or remote sensor can be directly connected to the glove box using the KF-40 flange. The remote version oxygen sensor can be placed in a glove box through our sampling/calibration module.



GPR-1500 GB GPR-2500 GB
range 0-10, 0-100, 0-1000 ppm, 0-1%,
0-25% (calibration only)
0-1%, 0-5%, 0-10%, 0-25%
precision Under constant conditions,<selected range='' 2%=''> precision
response time T90<10 seconds=''> response time
recovery time 60 seconds in air to<10='' ppm=''><1='' hour nitrogen purge=''> Not applicable
Sensitivity (LDL) 0.05 ppb 0.01%
linear <Scale='' 1%=''> <Scale='' 1%=''>
Sensor Model GPR-12-333-M

XLT-12-333-M is used for gas content>0.5% CO2
GPR-11-32-4

XLT-11-24-4 is used for gas content>0.5% CO2
Sensor lifespan @ 25 º C (77 ° F) and 1 atm 24 months in<1000='' ppm='' o2='' 6 months in the air=''> GPR-11-32-4 32 months in the air
XLT-11-24-4 24 months in the air
Calibration interval 30 days 31 days
intake pressure Nominal air pressure
Direct system: 0.34-2 barg (5-30 PSI) with vent holes
Nominal air pressure
Direct system: 0.34-2 barg (5-30 PSI) with vent holes
flow velocity Environmental monitoring or circulation system 0.5-1 Nl/min (1-2 SCFH) Environmental monitoring or circulation system 0.5-1 Nl/min (1-2 SCFH)
Gas connection KF 40 flange or 1/8 'compression pipe fittings (with straight through shell) KF 40 flange or 1/8 'compression pipe fittings (with straight through shell)
Liquid-contacting part GPR-1500 GB Stainless Steel GPR-2500 GB Delrin GPR-1500 GB Stainless Steel GPR-2500 GB Delrin
display Graphic LCD 7 x 3.5cm (2.75 x 1.375 '); Resolution 0.001 Graphic LCD 7 x 3.5cm (2.75 x 1.375 '); Resolution 0.002
shell Painted aluminum, 7.6 x 10.1 x 5.1cm (3 x4 x2 ') Painted aluminum, 7.6 x 10.1 x 5.1cm (3 x4 x2 ')
weight 900g (2lbs) 900g (2lbs)
compensation temperature temperature
signal output 4-20mA (loop power supply) 4-20mA (loop power supply)
call the police none none
Operating Temperature GPR sensor: 5 ° C to 45 ° C (41 ° F to 113 ° F)
XLT sensor: -10 ° C to 45 ° C (14 ° F to 113 ° F)
GPR sensor: 5 ° C to 45 ° C (41 ° F to 113 ° F)
XLT sensor: -10 ° C to 45 ° C (14 ° F to 113 ° F)
power supply 18-24 V DC two-wire circuit 18-24 V DC two-wire circuit
Regional classification general purpose general purpose