Oxygen Monitor - AII GPR-1500 GB/2500 GB
Oxygen Monitor - AII GPR-1500 GB/2500 GB Features Measurement Range from 0-10ppm up to 0-25% O2 Accuracy 2% better than range Sensor Life 24 months (under normal conditions) 4-20 mA Output 18-24V Loop Powered XLT Sensor can be used for CO2 background gas
Oxygen Monitor - AII GPR-1500 GB/2500 GB
This oxygen transmitter is particularly suitable for measuring oxygen inside glove boxes, ranging from air levels (21% oxygen content) to ppm levels (0-10 ppm oxygen content). It is easy to install and matches the needs of glove box operators. The analyzer or remote sensor can be directly connected to the glove box using the KF-40 flange. The remote version oxygen sensor can be placed in a glove box through our sampling/calibration module.
| GPR-1500 GB | GPR-2500 GB | |
| range | 0-10, 0-100, 0-1000 ppm, 0-1%, 0-25% (calibration only) |
0-1%, 0-5%, 0-10%, 0-25% |
| precision | Under constant conditions,<selected range='' 2%=''> | precision |
| response time | T90<10 seconds=''> | response time |
| recovery time | 60 seconds in air to<10='' ppm=''><1='' hour nitrogen purge=''> | Not applicable |
| Sensitivity (LDL) | 0.05 ppb | 0.01% |
| linear | <Scale='' 1%=''> | <Scale='' 1%=''> |
| Sensor Model | GPR-12-333-M XLT-12-333-M is used for gas content>0.5% CO2 |
GPR-11-32-4 XLT-11-24-4 is used for gas content>0.5% CO2 |
| Sensor lifespan @ 25 º C (77 ° F) and 1 atm | 24 months in<1000='' ppm='' o2='' 6 months in the air=''> | GPR-11-32-4 32 months in the air XLT-11-24-4 24 months in the air |
| Calibration interval | 30 days | 31 days |
| intake pressure | Nominal air pressure Direct system: 0.34-2 barg (5-30 PSI) with vent holes |
Nominal air pressure Direct system: 0.34-2 barg (5-30 PSI) with vent holes |
| flow velocity | Environmental monitoring or circulation system 0.5-1 Nl/min (1-2 SCFH) | Environmental monitoring or circulation system 0.5-1 Nl/min (1-2 SCFH) |
| Gas connection | KF 40 flange or 1/8 'compression pipe fittings (with straight through shell) | KF 40 flange or 1/8 'compression pipe fittings (with straight through shell) |
| Liquid-contacting part | GPR-1500 GB Stainless Steel GPR-2500 GB Delrin | GPR-1500 GB Stainless Steel GPR-2500 GB Delrin |
| display | Graphic LCD 7 x 3.5cm (2.75 x 1.375 '); Resolution 0.001 | Graphic LCD 7 x 3.5cm (2.75 x 1.375 '); Resolution 0.002 |
| shell | Painted aluminum, 7.6 x 10.1 x 5.1cm (3 x4 x2 ') | Painted aluminum, 7.6 x 10.1 x 5.1cm (3 x4 x2 ') |
| weight | 900g (2lbs) | 900g (2lbs) |
| compensation | temperature | temperature |
| signal output | 4-20mA (loop power supply) | 4-20mA (loop power supply) |
| call the police | none | none |
| Operating Temperature | GPR sensor: 5 ° C to 45 ° C (41 ° F to 113 ° F) XLT sensor: -10 ° C to 45 ° C (14 ° F to 113 ° F) |
GPR sensor: 5 ° C to 45 ° C (41 ° F to 113 ° F) XLT sensor: -10 ° C to 45 ° C (14 ° F to 113 ° F) |
| power supply | 18-24 V DC two-wire circuit | 18-24 V DC two-wire circuit |
| Regional classification | general purpose | general purpose |