Radcal SRC-500 ionization chamber detection equipment from the United StatesRepresented by Love Instrument Network, it is Fluke ® Direct TI substitute product for 96010A ionization chamber. By using the same coefficient from Radcal, it can be applied to Fluke ® Radiation leakage detection system. Currently on sale, if you need to make a purchase, you can contact us through the customer service hotline of ai1718!

Radcal SRC-500 ionization chamber detection equipment from the United StatesProduct Introduction:
Radcal SRC-500 ionization chamber is Fluke ® Direct TI substitute product for 96010A ionization chamber. By using the same coefficient from Radcal, it can be applied to Fluke ® Radiation leakage detection system. This ionization chamber meets the leakage measurement requirements of 21 CFR 1020.30 (k). Our 10 × 6-500 ionization chamber is part of the Accu See full system, which can treat multiple systems as a single component leak measurement solution.

Radcal SRC-500 ionization chamber product introduction:
Any leakage radiation from the diagnostic source shall not exceed: the leakage radiation (from the diagnostic source component) measured at a distance of 1 meter from the X-ray tube component shall be 0.88 millirem (mR)/hour (i.e. 100 milliradians/hour). If the X-ray tube operates using tube potential technology, the maximum rated tube voltage of the diagnostic source component means that the maximum X-ray tube potential of the provided shell component must not exceed the maximum rated positive tube potential of the diagnostic source component. Compliance should be determined by the average measurement results within a 100 square centimeter area, and any linear dimension in that area should not exceed 20 centimeters. ”
Radcal SRC-500 ionization chamber product specifications from the United States:
| Specifications | |
| structure | Capacity: 500 cc (nominal) Ventilation: Open to air Incident surface: 50 × 200 mm (100 cm ²) Connection ports: Signal (BNC), High Voltage (BNC) Bias voltage: nominal+400 VDC, maximum ± 600 VDC |
| Nominal sensitivity | 1.84E-05 C/Gy(±5%)(1.61E-07 C/R) |
| Reference conditions | Compliant with IEC 61267 |
| Beam quality | RQR 8(100 kV,4 mm Al); Support RQR and RQA |
| Energy response | ± 5% (40-150 kV) (compliant with IEC 61267) |
| Dose rate response | <5% (maximum 5 Gy/h (570 R/h), @ 400 VDC bias) |
| Electrical leakage | @<50 fA at 400 VDC bias voltage |
| Electrometer (to be ordered separately) | |
| type | Pre amplifier for SRC-500 ionization chamber |
| Compatible Models | SRC-PA1 |
| application | Used for Fluke ® Radiation leakage detection system or component leakage measurement system |
| Installation method | Installed at the end of SRC-500 |
| connection interface | Signal (including BNC); Data: WPI-AMPHENOL 126-1427; Host: WPI 126-1429 or equivalent product (to be provided by the user) |
| Electrometer electrical parameters | |
| Nominal sensitivity | 2.27E+11 V/A(±1%) |
| Electrical leakage | <40 fA(8.3 mV),@25℃(1.25 mΩ 室) |
| zero offset | The maximum leakage is less than 10 mV (when the maximum leakage is 20 fA) |
| rise time | 220 ms(±10 ms) |