Salt containing single effect wastewater evaporatorPrecautions for operation:
The operation of the evaporator is a common unit operation, and the operator should achieve the following: "four" (understanding the structure, principle, performance, and application of the evaporator), "four" (operation, maintenance, and troubleshooting).
1. The evaporator of the driver: strictly follow the operating procedures. Before driving, carefully check for water in the heating chamber, inspect and prepare pumps, instruments, steam and condensate pipelines. Operate and monitor according to pre-set programs based on different control devices.
2. Operation of evaporator: Equipment operation must be carefully operated and strictly controlled. The operator should check the regulations and adjust the evaporator according to the time interval of operation, and record it. Parameters that are not easily changed when the device is in a stable operating state.
3. Evaporator: The evaporator should be stopped when the equipment has not started for a long time or needs to be evacuated for maintenance; Minor repairs and repairs only require a short-term parking device to keep the equipment in standby mode; For accident vehicles, it is difficult to predict every possible situation and emergency parking should be carried out.
4. The evaporator system should undergo daily maintenance: the main equipment evaporator is usually cleaned. (Also known as furnace washing), the method of washing efficiency is divided into two types: large and small washing.
Salt containing single effect wastewater evaporatorparameter
Parameters/Model |
WZ-300 |
WZ-500 |
WZ-750 |
WZ-1000 |
WZ-2000 |
WZ-3000 |
Evaporation capacity (kg/h) |
300 |
500 |
750 |
1000 |
2000 |
3000 |
Heating area (m2) |
5.2 |
8 |
12 |
16 |
32 |
51 |
Condensation area (m2) |
6 |
11 |
15 |
20 |
40 |
65 |
Steam consumption (kg/h) |
330 |
550 |
820 |
1100 |
2200 |
3300 |
Cooling water volume (t/h) |
6 |
10 |
15 |
20 |
40 |
60 |
Dimensions (m) |
2.5x1x3.2 |
2.7x1x3.5 |
3x1.2x3.7 |
3.2x1.2x4 |
4x1.2x4.7 |
5x1.4x5 |
We use a multi effect (usually 3-effect evaporation system) wastewater evaporator to achieve energy conservation and cost savings. A large number of wastewater projects can generate profits for enterprises, not only achieving good social and environmental benefits, but also good economic benefits.
Adopting a multi effect evaporation crystallization system can reduce operating costs, especially steam consumption; The use of OSLO type crystallizer for evaporation concentration is beneficial for obtaining crystals with uniform distribution and larger particle size, which is beneficial for subsequent filtration and drying, and can greatly reduce the energy consumption of subsequent processes.
The design of the crystallizer should consider both the formation of crystal nuclei in supersaturated solutions and the range of particle size required for these nuclei to grow to the desired product size. In the design of the crystallizer, we rely on computational fluid dynamics tools to comprehensively consider the influence of factors such as residence time, flow rate, equipment surface characteristics, pH value, etc. on the crystallization process, optimize the structure of the crystallizer, and provide good conditions for crystal growth.
Can achieve continuous operation, high production intensity, and high efficiency; Good mixing effect inside the device