Sentinel LNG ultrasonic low-temperature liquid flowmeter uses advanced digital signal processing and improved algorithms to measure flow, enabling the flowmeter to measure flow with abnormal response speed. The Sentinel LNG system adopts a compact design, integrating powerful power into a simple body and providing multiple standard output configurations. To ensure safety, the customer wiring section is independently set up. It can be installed on fuel cell components or at a distance of 50 feet (15 meters) from the equipment. Even if installed directly on the wall, the cable connection terminals can still be accessed.
Product Details

Sentinel LNG Ultrasonic Low Temperature Liquid Flow Meter


Sentinel LNGUsing cutting-edge digital signal processing and improved algorithms to measure flow, enabling flow meters to measure flow with abnormal response speeds.Sentinel LNGThe system adopts a compact design, integrating powerful power into a simple body and providing multiple standard output configurations. To ensure safety, the customer wiring section is independently set up. It can be installed on fuel cell components or at a distance from the equipment50foot(15Location beyond meters. Even if installed directly on the wall, the cable connection terminals can still be accessed. The complete diagnostic function can be checked locally on the display, throughPCRemote inspection or output through various digital interfaces for continuous verification and preventive maintenance.

Sentinel LNG Ultrasonic Low Temperature Liquid Flow Meter


Specifications

Operation and performance

fluid type

Liquid hydrocarbons

flow measurement

Related transit time patterns

precision

The flow rate is between 0.25% of the measured volume between 2 and 30 ft/s (0.5 and 10 m/s).

repetitiveness

±0.02%

process temperature

-200 ° to+120 ° C (-328 ° to 248 ° F)

ambient temperature

-40 ° to+60 ° C (-40 ° to 140 ° F)

Storage temperature

-40 ° to+80 ° C (-40 ° to+176 ° F)

power supply

• 100 to 240 VAC • 12 to 32 VDC

display

High contrast 128 x 64 pixel graphic display with LED lighting.

output

Two frequency/pulse outputs, isolated from DC electro-optical

Two alarm relays

• A 4/20 mA output

input

Two 4/20 mA and one 100 ohm RTD input for temperature, pressure, and density inputs (optional).

Three 4/20 mA inputs for temperature, pressure, and density inputs (optional)

Digital interface

• PanaLink via RS232/485/USB

HART output exceeds 4/20 mA

Modbus over RS232/485 (optional)


application

• Liquefied natural gas (LNG)

Low temperature fluid distribution

• Transfer of jurisdiction

• Verification of sea freight cargo