Stable testing of flame photometer (sodium flame gauge)Stable testing of flame photometer (sodium flame gauge)
Sodium flame photometer (flame photometer) is used as a mask particle filtration efficiency tester and mask leakage tester
meet the standard
YY/T0866-2024,GB2626-2019,GB19083,EN149
NIOSH 42CFR Part 84, GB/T32610-2016 Technical Specification for Daily Protective Masks
GB2626-2019 Respiratory protective equipment - Self suction filtering particulate matter respirator
GB19082-2009 Technical Requirements for Disposable Protective Fu
GB19083-2010yi Technical Requirements for Protective Masks
TAJ1001-2015 PM2.5 Protective Mask
YY0469-2011yi uses an external ke mask
Core parameters
Detection range: 5ng/m ^ 3~200mg/m ^ 3; Accuracy: ± 1%; Response time: ≤ 500ms
Sampling pump: adjustable range of 0.1L/min~4L/min; Accuracy: ± 0.05L/min (during stable operation); Work pressure: 0~10
KPa (applicable to positive/negative pressure sampling scenarios) generally
Instrument Features
The host adopts a 7-inch color capacitive touch LCD screen
It has the advantages of small size, easy operation, and stable reliability
Potassium and sodium can be detected simultaneously.
Flameout protection device and gas leak alarm, safe and reliable
Equipped with automatic calculation function for correlation coefficient
Equipped with USB data export and USB communication port
Equipped with cloud connectivity function
Host interface
measurement setup
Curve Details
New qu line
Cloud Interconnection
Host parameters
model |
SRT-6410 |
||
display mode |
Seven inch capacitive touch screen |
||
display results |
Concentration value/light intensity |
||
reading range |
0.000~999.9/0~65535 |
||
detection limit |
potassium |
≤0.004mmol/L |
|
sodium |
≤0.008mmol/L |
||
linear error |
potassium |
≤0.005mmol/L |
|
sodium |
≤0.03mmol/L |
||
response time |
≤8S |
||
minimum spray volume |
≤6ml/min |
||
stability |
Continuous injection of standard solution, with a relative large change in instrument readings of ≤ 3% within 15 seconds Measure once per minute for a total of 6 measurements. The relative large change in instrument readings is ≤ 15% |
||
repetitiveness |
Repeat the same standard solution for 7 consecutive independent measurements ≤ 3% |
||
Print function |
standard configuration |
optional |
|
Printer type |
Bluetooth printer |
Bluetooth printer |
|
USB data output |
have |
||
Linear regression automatic calculation |
have |
||