Ultrasonic energy metersummary:
It is used to measure the UV energy of different light sources, especially on printing machines. Ensure that the printing and drying processes achieve ideal quality control. The spectral range that can be measured by the energy meter is 250-410 nanometers, and the optimal sensing peak spectral output is 330 nanometers. The relative value of the additional amount of light incident during the exposure cycle is included. Due to the irregular radiation distribution of the light source and the different structural designs of different manufacturers. So that different readings may occur under the same measurement conditions.
Features:
The body is a straight through integrated structure, made by precision casting technology.
Hollow structure, truly unobstructed water flow, especially suitable for China's heating water quality and working conditions requirements, with less pressure loss.
Simple structure, easy installation and maintenance.
*Not affected by impurities, chemicals, and magnetic materials in the medium, the operation is very stable and reliable.
The measuring structure has no movable parts, wear and tear, and the measurement accuracy is not affected by the service life.
Adopting imported microcontrollers from the United States and advanced low-power design. Only battery power is needed.
Using German imported ultrasonic detection chips for higher accuracy.
It can be installed horizontally or vertically, which is extremely convenient and practical.
Dual use of hot and cold water, dual use of inlet and outlet water.
Multiple communication methods can be selected (RS485, M-BUS, GSM remote signal transmission) (additional installation required)
Ultrasonic energy meter
Operation Instructions:
Technical Specifications:
Measuring caliber |
DN6~DN300 | working power supply |
3.6V built-in battery |
measuring medium |
Cold water, hot water, or other liquids | display mode |
Chinese LCD display |
rated temperature |
2~95℃ | Display content |
Cooling capacity, heat, inlet temperature, outlet temperature, temperature difference, flow rate, water volume, working time, date |
rated pressure |
1.6Mpa | display unit |
℃,m3,kwh |
working environment |
0~50℃ IP65 | output signal |
4-20mA, RS485 (optional) |
Overall dimensions:

The nominal Tongjing |
DN15 |
DN20 |
DN25 |
DN32 |
DN40 |
DN50 |
DN65 |
|
Overall dimensions |
L |
130 |
130 |
130 |
160 |
180 |
200 |
200 |
W |
120 |
120 |
121 |
125 |
130 |
138 |
138 |
|
H |
86 |
86 |
89 |
98 |
109 |
170 |
170 |
|
connection method |
threaded connection |
flange connection |
||||||
G1/2” |
G3/4” |
G1” |
G11/4” |
G11/2” |
4-M16 |
4-M16 |
||
The nominal Tongjing |
DN80 |
DN100 |
DN125 |
DN150 |
DN200 |
DN250 |
DN300 |
|
Overall dimensions |
L |
225 |
250 |
250 |
300 |
350 |
400 |
400 |
W |
186 |
205 |
230 |
265 |
350 |
385 |
445 |
|
H |
210 |
220 |
235 |
270 |
320 |
395 |
475 |
|
connection method |
flange connectionpn1.6mpa |
flange connectionpn1.0mpa |
||||||
8-M16 |
8-M16 |
8-M16 |
8-M20 |
12-M20 |
12-M22 |
12-M22 |
||
Installation precautions:
There are several incorrect installation methods, please be very cautious and install correctly, otherwise it will damage the MKH ultrasonic thermometer.
Please do not hold the meter head with your hands before using a wrench to tighten the nut during installation. Because the header is made of plastic, it is easy to damage the header components. The correct way is to use a wrench to tighten the connecting pipe nuts on both sides;

When the heat meter is installed horizontally, the direction of the integrator is facing upwards. If the integrator is facing sideways, it will cause the transducers on both sides to not be on the same horizontal plane, and air may accumulate at the transducer at a higher height, resulting in inaccurate or inaccurate measurement of the heat meter;

When the heat meter is installed vertically, it must be installed on a straight pipeline with upward water flow, because the pipeline with downward water flow will be affected by the gravity of the earth, which will cause the water in the pipeline to be unable to fill the pipe section;
When installing the heat meter at the "U" - shaped pipe, please install the heat meter at the lowest point, as air may accumulate in the pipe at a higher location, causing the heat meter to not measure or measure accurately.
When installing a valve or other object on the heat meter, it is necessary to ensure that the distance between the meter box and the object is greater than 5 times the diameter of the pipe. When installing a valve or other object behind the meter, it is also necessary to ensure that there is a distance of at least 2 times the diameter of the pipe between the meter and the object, otherwise it may cause incorrect measurement of the heat meter.