Water cooled air conditioning equipment
Installation method of water-cooled air conditioning equipment
The conventional installation methods for water-cooled air conditioners (evaporative air conditioners) can be divided into.
Examples of water-cooled air conditioning equipment
Wall mounted installation, window installation, floor installation, star tile roof installation, floor mounted installation.
The installation types of effect design can be divided into direct air supply without going through pipelines, local area air supply, air-cooled air conditioning, bottom air outlet, and top air outlet installation technical requirements
Bottom air outlet of water-cooled air conditioner
Installation technical requirements for top and bottom air outlets
1. Use 40, 40, and 4-point iron frames to connect with walls or window panels using bolts.
2. All gaps are sealed with glass glue and cement sand.
The cross-sectional area of the air supply duct for environmentally friendly air conditioning should not be less than 0.45 square meters, and the top air outlet for water-cooled air conditioning.
4. The welding and installation of the triangular bracket must be firm.
The installation bracket must be level with the host.
All exterior wall air ducts must be properly waterproofed.
7. The bottom of the host and the contact part with the bracket must be cushioned with shock-absorbing pads.
The installation on the zinc iron tile shed should have sufficient strength to withstand the weight of the water-cooled air conditioning unit.
9. The size of the roof or roof opening should not exceed 20mm of the size of the air duct, otherwise waterproofing treatment cannot be done properly.
Adequate air intake and maintenance space should be left at different installation locations.
The cross-sectional area of the air duct entering the wall or window shall be determined according to the usage location, but shall not be less than 0.45 square meters.
The remote control receiver box is connected to the communication line and introduced into the room through the air outlet duct. It is installed in a position that is easy to receive remote control signals, and a 22mm hole must be opened on the air outlet duct and fixed in an appropriate position indoors.