Introduction: With the development of industrial production and the continuous improvement of people's living standards, it is urgent to control water pollution and develop and utilize water resources rationally.
For this reason, many units commonly adopt energy-saving equipment such as fiberglass cooling towers, implement internal water closed circuits, improve reuse rates, effectively reduce costs, and at the same time, turn people's desire to adjust the temperature, humidity, cleanliness, and noise impact of the surrounding environment into reality.
Fiberglass cooling tower is corrosion-resistant, high-strength, lightweight, small in size, occupies less space, beautiful and durable, and is easy to transport, install and maintain. Therefore, it is widely used in various sectors of the civil economy, especially suitable for cooling water systems such as air conditioning, refrigeration, air compression stations, and heating furnace condensation processes.
Circular counter current fiberglass cooling tower
The circular counterflow fiberglass cooling tower adopts counterflow gas heat exchange technology, and the packing material uses modified polyvinyl chloride waveplates to diffuse the water spraying area; By rotating the water distribution method, uniform water distribution and cooling effect can be achieved. Our factory has made partial improvements to the exterior design of this series of products, making them more reliable, durable, and easy to install
main purpose
(1) DBNL3 series low-noise fiberglass cooling tower - suitable for general cooling applications such as air conditioning refrigeration units with water temperature drops of 3-8 degrees. (2) CDBNL3 series ultra-low noise fiberglass cooling tower - suitable for hotels, hospitals, and public buildings with stricter noise requirements that are closer to residential areas.
(3) GBNL3 series medium high temperature industrial fiberglass cooling tower - suitable for industrial water cooling systems with a water temperature drop of 10-25 degrees. Model composition
There are three main series of circular counterflow fiberglass cooling towers: DBNL3, CDBNL3, and GBNL3.
Performance and Selection
1. Design parameters:
1) Standard operating conditions: Inlet water temperature t1=37 ℃, outlet water temperature t2=32 ℃, design wet bulb temperature τ=28 ℃, i.e. water temperature Δ t=5 ℃, cooling amplitude height t2- τ=5 ℃
2) Medium temperature condition: Inlet water temperature t1=43 ℃, outlet water temperature t2=33 ℃, design wet bulb temperature τ=28 ℃, i.e. water temperature Δ t=10 ℃, high cooling amplitude t2- τ=6 ℃
3) High temperature condition: inlet water temperature t1=60 ℃, outlet water temperature t2=35 ℃, design wet bulb temperature τ=28 ℃, i.e. water temperature Δ t=25 ℃, high cooling amplitude t2- τ=8 ℃