18 cubic stainless steel fire water tank box pump integration

NegotiableUpdate on 01/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The integration of 18 cubic stainless steel fire water tank and pump is a combination of 18m #179; The volume stainless steel water tank is integrated with the fire pump set, pressure stabilization system, and intelligent control system as a fire pressure boosting and stabilization equipment. It mainly provides initial water (about 30 minutes) and stable water pressure for the building fire protection system, meeting the needs of fire hydrants and automatic sprinkler systems.
Product Details

18 cubic stainless steel box pump integration: full analysis of intelligent fire water supply system

1、 Product definition and core parameters

18 cubic stainless steel box pump integratedIt is a fire pressure boosting and stabilizing equipment that integrates an 18m ³ stainless steel water tank with a fire pump set, stabilizing system, and intelligent control system. It mainly provides initial water supply (about 30 minutes) and stable water pressure for building fire protection systems, meeting the needs of fire hydrants and automatic sprinkler systems.
Core parameters
  • Water tank capacity: 18m ³ (18 tons of water), meeting the initial fire water demand

  • Common sizesApproximately 5 x 4 x 2m (length x width x height), covering an area of approximately 20 square meters

  • materialMainstream 304 stainless steel (food grade), 316L is selected for high corrosion environment, and BDF composite plate is selected for economical type

  • design pressure0.3-1.0MPa (depending on building height), ensuring that the most unfavorable point pressure is ≥ 0.15MPa

  • flow rangeMain fire pump 18-40L/s, sprinkler pump 3.6-15L/s

  • pump head:30-120m, Meet the requirements of building height and pipeline loss

  • powerMain pump 4-45kW, stabilizing pump 0.75-7.5kW


2、 Detailed explanation of system composition18 cubic stainless steel fire water tank box pump integration

1. Water tank system (core water storage unit)

Comparison of Material Selection
material feature Applicable scenarios lifespan
304 stainless steel Containing Cr18% and Ni8%, resistant to freshwater corrosion, meeting food grade standards Ordinary buildings, residences, and offices 15-20 years
316L stainless steel Containing Mo2%, strong resistance to chloride ion corrosion (resistant to seawater/saltwater) Coastal areas, chemical zones, high humidity 20-25 years
BDF composite board Stainless steel inner layer+galvanized steel plate outer layer, high strength, low cost Underground installation, non potable water system 10-15 years
structural design
  • Prefabricated modular structure (1m × 1m, 1m × 0.5m standard plates), bolted connection, no welding stress

  • Internally equipped with galvanized tie bars and column supports, the top can withstand soil pressure (buried type)

  • Bottom sloping design for easy drainage and cleaning

  • Water level control system: float valve/solenoid valve for water inlet, overflow pipe for overflow prevention, water level sensor (accuracy ± 1mm)

2. Pump set system (pressure boosting and stabilizing core)

Typical configuration
Pump type quantity parameter function
Fire hydrant main pump 2 units (1 in use and 1 as backup) Q=18m³/h(5L/s),H=30m,N=4kW Provide water for the fire hydrant system during a fire
main spray pump 2 units (1 in use and 1 as backup) Q=3.6m³/h(1L/s),H=30m,N=0.75kW Provide water for automatic sprinkler system in case of fire
pressure stabilizing pump 1-2 units Small flow rate and high head, Q=5-10L/s,H=40-60m,N=1.5-7.5kW Daily maintenance of pipeline pressure and reduction of main pump start-up
pressure tank 1-2 units Diaphragm type, volume 150-300L, working pressure 0.6-1.0MPa Storage of initial water volume, buffering water hammer effect
Characteristics of water pump
  • Dry motor design, no need to exhaust air, can run directly in water

  • Pump casing: ductile iron or 304 stainless steel, impeller: bronze or stainless steel

  • Shaft seal: mechanical seal, leak proof, suitable for long-term operation

3. Intelligent control system (central brain)

core component
  • PLC control cabinet (IP68 protection): built-in fire protection program, real-time monitoring and control

  • Touch screen human-machine interface: displays parameters, alarm information, supports local operation

  • Pressure/liquid level sensor group: monitoring pipeline pressure (accuracy ± 0.02MPa) and water tank level

  • Remote monitoring module (optional): 4G communication, supports mobile APP/PC monitoring

Main functions
  • Automatic voltage stabilization: maintain the pipeline pressure at the set value (± 0.02MPa)

  • Water level control: low water level alarm, high water level overflow protection

  • Intelligent rotation of pump sets: Balance the running time of each pump and extend the overall lifespan

  • Fault self diagnosis: Display the fault location, trigger the sound and light alarm, and upload it

3、 Working principle and process

1. Daily voltage stabilization mode (99% of the time)

  • The stabilizing pump continues to operate, maintaining the pipeline pressure at the set value (such as 0.8MPa)

  • The pressure tank stores approximately 100L of emergency water to reduce frequent pump starts

  • When there is a slight water leakage in the system, it is supplemented by the pressure tank and the stabilizing pump

2. Fire initiation mode (critical response)

Fire hydrant/sprinkler outlet → pipeline pressure drops →
  1. The pressure sensor detects that the pressure is below the start-up threshold (such as 0.7MPa)

  2. PLC controller starts 1 fire hydrant pump/sprinkler pump

  3. If the pressure continues to decrease, start the backup pump (multiple pumps in parallel)

  4. The water tank continues to supply water. When the water level drops to the low water level line, stop the water pump to prevent dry burning

3. System recovery mode

  • After extinguishing the fire, manually/automatically reset

  • Restart the stabilizing pump to restore the pressure in the pipeline network

  • The water tank automatically replenishes water to the set water level

4、 Model Analysis (XBF-18-18/3.6-30-I)

  • WHDXBFCode for integrated pump station of intelligent box pump with fire pressure stabilization

  • 18Effective volume of water tank (18m ³)

  • 18/3.6The flow rate of the fire main pump is 18m ³/h, and the flow rate of the sprinkler main pump is 3.6m ³/h

  • 30Pump head (30m)

  • IOne in use, one backup configuration

5、 Application scenarios and advantages

Applicable scenarios:

  1. Multi story/small high-rise residential buildingsProvide water for fire hydrants and sprinkler systems

  2. Commercial complex/underground garageUnderground design saves space, with automatic sprinkler matching

  3. Small industrial plantMeets fire safety regulations and is corrosion-resistant (when 316L is selected)

  4. Renovation of old buildingsNo need to build a new pump room, short construction period (3-7 days)

Product advantages vs. traditional fire protection systems:

Comparison item Integrated 18 cubic box pump Traditional concrete water tank+pump room
construction period 3-7 days (factory prefabrication+on-site installation) 3-6 months (civil engineering+equipment)
floor area Approximately 20 square meters (including maintenance access) 50-100 square meters (including water tank and pump room)
investment cost Reduce by 40-60% (reduce civil engineering costs) High (reinforced concrete+independent equipment)
Water quality assurance Fully enclosed stainless steel, no secondary pollution Concrete water tanks are prone to algae growth
intelligentization Fully automatic control+remote monitoring Mainly manual operation, limited monitoring
Maintenance difficulty Low (modular design, easy to maintain) High (requires regular cleaning of the pool)
adaptability Can be buried or above ground, suitable for small spaces Due to terrain limitations, a separate pump room is required



18 cubic stainless steel fire water tank box pump integration