2010 portable gas dilution calibrator

NegotiableUpdate on 01/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Instrument Introduction: Users can easily calibrate gas dilution, ozone, and GPT using the 2010 portable gas dilution calibrator. The 2010 portable gas dilution calibrator has a small size and lightweight, which can well meet the portable requirements of users. The 2010 calibration system is convenient and effective, and can accurately control the dilution of standard gases for calibration of environmental air and pollution source analyzers. The 2010 portable gas dilution calibrator uses built-in microprocessor technology to enhance the accuracy of the instrument and control over the calibration system. The instrument can be remotely controlled manually, automatically, or semi automatically. The calibrator can generate and store 20 calibration sequences, each of which can set 20 dilution ratios. Users can input calibration parameters using the buttons on the front panel and external keyboard, and control the calibration action through a series of interfaces. The gas path system of the 2010 portable gas dilution calibrator uses a mass flow controller to measure gas flow rate for linear calibration. The design of the 2010 portable gas dilution calibrator exceeds the requirements of the EPA standard calibration method. All mass flow controllers are calibrated through NIST's standardized transmission. Standard configuration: Air circuit section:
Product Details

Instrument Introduction:
Users can conveniently calibrate gas dilution, ozone, and GPT using the 2010 portable gas dilution calibrator. The 2010 portable gas dilution calibrator has a small size and lightweight, which can well meet the portable requirements of users. The 2010 calibration system is convenient and effective, and can accurately control the dilution of standard gases for calibration of environmental air and pollution source analyzers.
The 2010 portable gas dilution calibrator uses built-in microprocessor technology to enhance the accuracy of the instrument and control over the calibration system. The instrument can be remotely controlled manually, automatically, or semi automatically. The calibrator can generate and store 20 calibration sequences, each of which can set 20 dilution ratios. Users can input calibration parameters using the buttons on the front panel and external keyboard, and control the calibration action through a series of interfaces.
The gas path system of the 2010 portable gas dilution calibrator uses a mass flow controller to measure gas flow rate for linear calibration.
The design of the 2010 portable gas dilution calibrator exceeds the requirements of the EPA standard calibration method. All mass flow controllers are calibrated through NIST's standardized transmission.
Standard configuration:
Gas path section:

*Dilution gas mass flow controller, 0-10 SLM;

*Source gas mass flow controller, 0-100 SCCM;

*Two calibration gas input interfaces and one cleaning interface;

*4 output interfaces and 1 air outlet;

*1 dilution gas input interface;


Control device:

*High brightness color display screen (displayed as black and white EL screen);

*42 key touch keyboard;

*8-bit digital I/O interface;

*2 serial data communication interfaces;

*External PC keyboard input interface;

*Parallel printer interface;

*(Zero) Air source (equipment) control interface;


Power supply section:

*Standard 98-264 VAC, 150-300 VA, 50/60 Hz operation;


Optional configuration:

*Dilution gasMass flow controller, range 0-20 SLM;
*Source gas mass flow controller, with a range of 0-1 SLM;
*The second source gas mass flow controller has a range of 0-1 SLM;
*Additional steel cylinders or source gas inlet ports that can be added;
*Interface of infiltration furnace equipment;
*24 bit I/O interface;
*6 external solenoid valve drive interfaces, drive power: 24VDC/3W;
*Built in ozone generator;
*Ozone generator UV closed-loop control system;
*Side mounted for easy carrying;
*Durable transport box;
*Installation of 5.25 "H U chassis (2010D) for models with brackets;

Product specifications:
Dilution system:
*Dilution gas inlet: 1 standard interface;
*Source gas inlet: 2 standard interfaces, 1 cleaning interface;
Optional source gas inlet: 4 interfaces;
*Dilution gas mass flow controller: 0-10 SLPM; Optional range 0-20 SLPM;
*Source gas mass flow controller: 0-100 SCCM; Optional range 0-1 SLPM;
*Second source gas mass flow controller: 0-1 SLPM;
*Flow accuracy: ≤± 1% of full scale;
*Flow reproducibility: ≤± 0.15% of full scale;
*Linear: ≤± 0.5% of full scale;
*Input pressure: 12-35 PSI;
*Output interface: 4 standard output ports;

*Optional input interfaces: 4;


Optional built-in ozone generator:

*Output: 0.05-1.5 ppm@5 SLPM;

*Accuracy: ± 2% or ± 3 ppb@5 SLPM;

*Flow rate: 100 SCCM, ± 1 SCCM;

*UV lamp temperature: 50 ℃, ± 0.1 ℃;


Calibration interface:

*Operation: Manual control through 42 key touch keyboard;

*Calibration settings: 20 factory set calibration sequences, with a maximum of 20 calibration points per sequence;

*Calibration type: gas dilution, ozone, GPT;

*Gas setting: 1 dilution gas, 20 source gases;

*Automatic calibration: Provide 20 timed calibration paths based on user set calibration events within 7 days;

*Digital I/O: 8-bit I/O control calibration function;

* Optional I/O: Additional 16 bit I/O, providing a total of 24 bit I/O;

*(Serial) interface: RS232;

Calibration system:

*Operating (environmental) temperature: 5-40 ℃;

*Specification size: 6.2 "(15.6 cm) H × 14.3" (36.4 cm) W × 12.4 "(31.6 cm) D;

*Weight: 19 lbs. (8.6 kg);

*Input voltage: 98-264 VAC, 100 VA, 50/60 Hz operation.