The GC 5000 organic sulfur online chromatographic monitoring system was developed, designed, and manufactured by AMA, a German company. The instrument has sub ppt level detection sensitivity and can analyze and test methyl mercaptan, ethyl mercaptan, dimethyl sulfide (methyl sulfide), carbon disulfide, diethyl sulfide (ethyl sulfide), dimethyl disulfide, benzene, and toluene in ambient air. It can also monitor other organic sulfur compounds. The online chromatographic monitoring system has passed EN 14662-3 certification.

The core components mainly include the GC 5000 organic sulfide chromatographic analyzer host and the DIM 200 calibration module.

Instrument characteristics:

*Can be installed in a 19 '' standard cabinet;

*This analyzer can automatically complete the sampling, enrichment, desorption, and analysis processes of sub ppb level organic compounds and organic sulfides;

*Measurement range: 0-300ppb;

*Detection limits: 0.9ppb for methyl mercaptan and 0.3ppb for carbon disulfide;

*Reproducibility:<3% methyl mercaptan at 10 ppb;

*Cycle time of 30 minutes;

*Continuous control of carrier gas pressure;

*Control analysis and operation programs through built-in industrial computers;

*The user interface of the analysis and chromatography software is easy to operate;

*Data transmission can use RS232 and GESYTEC I (Bayer Hessen) or GESYTEC II protocols;

*Automatic calibration or calibration based on system conditions;

*External keyboard and mouse interface;

*Ethernet interface, capable of meeting the application needs of various remote control software;

*Are all flow paths that come into contact with the target compound covered with Sulfinert? Coating to avoid contact between organic sulfides and metal surfaces, such as ten way valves with built-in sample gas pipelines and fittings;

Note: Sulfonert is a registered trademark of RESTEK Limited.

Sampling and Enrichment:

Sampling:

Technical parameters:
Technical features:

*Use low maintenance membrane pumps for automatic sampling;

*MFC precisely controls the sampling flow rate and volume, with no impact on changes in air pressure and temperature;

*Sampling time: 0-99 minutes (adjustable);

*Sampling flow rate: 10~50mL/min (adjustable);

*Sampling volume: typical 200~800mL (adjustable);

Single level enrichment:

*Single stage enrichment module, used for the enrichment of organic sulfides, combining precise temperature control and electronic refrigeration;

*Enrichment temperature: 5-30 ° C, the integrated device automatically completes thermal analysis and injection, with a maximum analysis temperature of 350 ° C and a heating rate of up to 40 ° C/s, ensuring rapid sample injection and excellent peak shape;

Gas chromatography analysis:

*The length of the capillary column in the chromatography box is 60m, and the linear program heating is carried out in 3 steps;

*Column box temperature range: 40-210 ° C, heating rate: 1-25 ° C/min, increasing by 1 ° C/min;

*Rapid cooling;

*Backblowing column can intercept and blow back xylene and high boiling point organic compounds;

*Electric ten way valve, valve box temperature range: 30-150 ° C.

PID detector:

*PID detector combined with packed column or capillary column to complete analysis work;

*Using an electrodeless RF excited UV lamp to achieve high-intensity UV output and longer lifespan;

*The constant temperature module of the detector ensures stable and controllable temperature, thereby obtaining stable detection signals;

*Minimum detection limit: ≤ 0.01ppb (taking benzene as an example).

*19 '' standard rack mounted installation;

*Appearance size: 6U high, 600mm deep;

*Weight: 33kg;

*Power supply: 220 VAC, 50 Hz;

*Carrier gas: N2

I/O module (optional):

*Set up and control the I/O module through chromatography software;

*Digital input is used to control the chromatograph;

*Digital output status information, sampling flow rate, and alarm information, etc;

*8 analog outputs, 4-20 mA/0-5 V/0-10 V;

DIM200 dilution calibration module/Sulfinert version

*19 '' standard cabinet installation, height 3U

*Anti splash film keyboard and menu oriented user interface, which can be quickly set and operated;

*The LCD screen directly displays the current calibration level, component concentration, parameters, instrument operating status, and error information;

*MFC can accurately control the flow rate of source gas and zero gas. The software controls the built-in solenoid valve to switch between sample gas, zero gas, and standard gas paths;

*The calibration module can be independently or remotely controlled through digital I/O ports;

*Any AMA GC system can control DIM200 through internal bus communication;

*Independently operated or remotely controlled through digital I/O ports, up to 5 calibration levels can be achieved;

*Through remote control calibration using the AMA GC system, up to 20 calibration levels can be achieved;

*Through the AMA GC control software, the calibration module can be quickly set up and can be operated independently or in menu oriented mode;

*Capable of automatically calibrating or validating the AMA GC analysis system;

*All parts of MFC that come into contact with the target compound are covered with a Sulfinert coating;

Flow control:

*The standard gas flow control uses digital MFC, and the contact part is made of stainless steel material;

Flow range: 2~100mL/min;

Accuracy: ± 0.5% of full scale;

Reproducibility: ± 0.25%;

*Zero gas/dilution gas MFC, with aluminum contact area;

Flow range: 100~5000 mL/min;

Accuracy: ± 0.5% of full scale;

*Dilution ratio: 1~2500;

Technical parameters:

*19 '' standard cabinet installation;

*Exterior dimensions: height 3U, depth 400mm; weight: approximately 6kg;

*Power supply: 220VAC, 50Hz;

*Sample gas, zero gas, and standard gas sources need to be provided;

*Gas connection: 1/8 "through plate joint, 1/4" through plate joint (zero gas and bypass).