High flow, high-temperature resistant, non clogging submersible sewage pumpIntroduction:
This product is a new generation of pump products developed based on the technology of sewage pumps, combined with the actual characteristics of domestic water pumps and the combination of high-temperature resistant motors. It has the characteristics of energy saving, anti winding, no blockage, automatic installation, and automatic control. It has unique advantages in the disposal of solid particles and long fiber waste. Suitable for conveying granular wastewater in industries such as chemical, petroleum, pharmaceutical, mining, papermaking, cement plants, steel mills, power plants, coal processing, as well as urban sewage treatment plant drainage systems, municipal engineering, construction sites, etc. It is a reliable product for environmental protection, chemical industry, and energy.
Structural diagram of high flow unobstructed submersible sewage pump:

The WQ type unobstructed submersible sewage pump consists of a motor and a pump, which are separated by an oil isolation chamber and mechanical seal components. It is an electromechanical integrated product, and the motor and pump share the same shaft (rotor). The entire length of the water pump is short and the structure is compact. Equipped with multiple protective devices to ensure safe and reliable operation of the pump. The main functions of its components are as follows:
Signal line 1: Equipped with a fully protected water pump control cabinet to protect the pump, including water leakage, phase failure, short circuit, overheating, motor overload, and other items.
Motor stator 8: adopts B-level or F-level insulation.
Leakage probe 11: This component is installed in the oil chamber. When the mechanical seal is damaged and water enters the oil chamber, the probe can send a signal to the control system to protect the pump.
Mechanical Seal 13: Adopting a dual channel series seal and using a new type of hard and corrosion-resistant tungsten carbide material, it has the characteristics of reliable sealing, wear resistance, and long service life.
Impeller 17: The impeller adopts a single or double channel structure, which has strong passing capacity and can pass large materials and fiber waste, reducing blockage and entanglement failures.
Pump body 15: Paired with the impeller, the pump has high efficiency.
Sealing ring 18: installed at the mouth ring of the pump body. When the impeller wears out the mouth ring due to operation, the sealing ring can be replaced to ensure efficient operation of the pump.
High flow, high-temperature resistant, non clogging submersible sewage pumpFeatures:
1. By using the submersible automatic mixing sewage pump to mix the discharge pressure, the sediment in the sewage tank is stirred evenly, truly achieving the goal of discharging the sediment in the sewage tank.
2. The design of anti clogging hydraulic components for large flow channels greatly improves the ability of pollutants to pass through, effectively passing through 5 times the fiber material of the pump diameter and solid particles with a diameter of about 50% of the pump diameter.
3. Adopting high-temperature resistant submersible motors, with reasonable design, high efficiency, and energy saving.
4. The mechanical seal adopts a dual channel series seal, made of hard and corrosion-resistant tungsten carbide, which is durable and wear-resistant. It can ensure the safe and continuous operation of the submersible automatic mixing sewage pump for more than 8000 hours.
5. The submersible sewage pump has a compact structure, small volume, easy movement, and simple installation. It does not require the construction of a pump room and can work underwater, reducing project costs.
6. There is an oil-water probe installed in the oil chamber to protect the submersible automatic mixing sewage pump.
7. It can be equipped with a fully automatic safety protection control cabinet to protect the submersible automatic mixing sewage pump from water leakage, electric leakage, overload, and overheating, improving the safety and reliability of the product.
8. The float switch can automatically control the stop and start of the submersible automatic mixing sewage pump according to the required water level changes, without the need for dedicated personnel to supervise.
9. The motor can adopt a water jacket external circulation cooling system to ensure the safe operation of the submersible automatic mixing sewage pump in a dry state without water.
10. The dual rail automatic coupling installation system brings great convenience to the installation and maintenance of submersible automatic mixing and sewage pumps, and people do not need to enter the sewage pit for this.
11. There are two installation methods: fixed automatic coupling installation and mobile free installation, which can meet different usage scenarios.
Technical selection of high displacement, high-temperature resistant and non clogging submersible sewage pump:
model |
caliber |
traffic |
head |
power |
speed |
efficiency |
25WQR8-22-1.1 |
25 |
8 |
22 |
1.1 |
2825 |
38.5 |
32WQR12-15-1.1 |
32 |
12 |
15 |
1.1 |
2825 |
40 |
40WQR15-15-1.5 |
40 |
15 |
15 |
1.5 |
2840 |
45.1 |
40WQR15-30-2.2 |
40 |
15 |
30 |
2.2 |
2840 |
48 |
50WQR20-7-0.75 |
50 |
20 |
7 |
0.75 |
1390 |
54 |
50WQR10-10-0.75 |
50 |
10 |
10 |
0.75 |
1390 |
56 |
50WQR20-15-1.5 |
50 |
20 |
15 |
1.5 |
2840 |
55 |
50WQR15-25-2.2 |
50 |
15 |
25 |
2.2 |
2840 |
56 |
50WQR18-30-3 |
50 |
18 |
30 |
3 |
2880 |
58 |
50WQR25-32-5.5 |
50 |
25 |
32 |
5.5 |
2900 |
53 |
50WQR20-40-7.5 |
50 |
20 |
40 |
7.5 |
2900 |
55 |
65WQR25-15-2.2 |
65 |
25 |
15 |
2.2 |
2840 |
52 |
65WQR37-13-3 |
65 |
37 |
13 |
3 |
2880 |
55 |
65WQR25-30-4 |
65 |
25 |
30 |
4 |
2890 |
58 |
65WQR30-40-7.5 |
65 |
30 |
40 |
7.5 |
2900 |
56 |
65WQR35-50-11 |
65 |
35 |
50 |
11 |
2930 |
60 |
65WQR35-60-15 |
65 |
35 |
60 |
15 |
2930 |
63 |
80WQR40-7-2.2 |
80 |
40 |
7 |
2.2 |
1420 |
52 |
80WQR43-13-3 |
80 |
43 |
13 |
3 |
2880 |
50 |
80WQR40-15-4 |
80 |
40 |
15 |
4 |
2890 |
57 |
80WQR65-25-7.5 |
80 |
65 |
25 |
7.5 |
2900 |
56 |
100WQR80-10-4 |
100 |
80 |
10 |
4 |
1440 |
62 |
100WQR110-10-5.5 |
100 |
110 |
10 |
5.5 |
1440 |
66 |
100WQR100-15-7.5 |
100 |
100 |
15 |
7.5 |
1440 |
67 |
100WQR85-20-7.5 |
100 |
85 |
20 |
7.5 |
1440 |
68 |
100WQR100-25-11 |
100 |
100 |
25 |
11 |
1460 |
65 |
100WQR100-30-15 |
100 |
100 |
30 |
15 |
1460 |
66 |
100WQR100-35-18.5 |
100 |
100 |
35 |
18.5 |
1470 |
65 |
125WQR130-15-11 |
125 |
130 |
15 |
11 |
1460 |
62 |
125WQR130-20-15 |
125 |
130 |
20 |
15 |
1460 |
63 |
150WQR145-9-7.5 |
150 |
145 |
9 |
7.5 |
1440 |
63 |
150WQR180-15-15 |
150 |
180 |
15 |
15 |
1460 |
65 |
150WQR180-20-18.5 |
150 |
180 |
20 |
18.5 |
1470 |
75 |
150WQR180-25-22 |
150 |
180 |
25 |
22 |
1470 |
76 |
150WQR130-30-22 |
150 |
130 |
30 |
22 |
1470 |
75 |
150WQR180-30-30 |
150 |
180 |
30 |
30 |
1470 |
73 |
150WQR200-30-37 |
150 |
200 |
30 |
37 |
1480 |
70 |
200WQR300-7-11 |
200 |
300 |
7 |
11 |
970 |
73 |
200WQR250-11-15 |
200 |
250 |
11 |
15 |
970 |
74 |
200WQR400-10-22 |
200 |
400 |
10 |
22 |
1470 |
76 |
200WQR400-13-30 |
200 |
400 |
13 |
30 |
1470 |
73 |
200WQR250-15-18.5 |
200 |
250 |
15 |
18.5 |
1470 |
72 |
200WQR300-15-22 |
200 |
300 |
15 |
22 |
1470 |
73 |
200WQR250-22-30 |
200 |
250 |
22 |
30 |
1470 |
71 |
200WQR350-25-37 |
200 |
350 |
25 |
37 |
1980 |
75 |
200WQR400-30-45 |
200 |
400 |
30 |
45 |
1480 |
70 |
250WQR600-9-30 |
250 |
600 |
9 |
30 |
980 |
74 |
250WQR600-12-37 |
250 |
600 |
12 |
37 |
1480 |
78 |
250WQR600-15-45 |
250 |
600 |
15 |
45 |
1480 |
75 |
250WQR600-20-55 |
250 |
600 |
20 |
55 |
1480 |
73 |
250WQR600-25-75 |
250 |
600 |
25 |
75 |
1480 |
73 |
250WQR800-12-45 |
250 |
800 |
12 |
45 |
980 |
76 |
300WQR500-15-45 |
300 |
500 |
15 |
45 |
980 |
70 |
300WQR800-15-55 |
300 |
800 |
15 |
55 |
980 |
73 |
300WQR600-20-55 |
300 |
600 |
20 |
55 |
980 |
75 |
300WQR800-20-75 |
300 |
800 |
20 |
75 |
980 |
78 |
300WQR950-20-90 |
300 |
950 |
20 |
90 |
980 |
80 |
300WQR1000-25-110 |
300 |
1000 |
25 |
110 |
980 |
82 |
350WQR1100-10-55 |
350 |
1100 |
10 |
55 |
980 |
84.5 |
350WQR1500-15-90 |
350 |
1500 |
15 |
90 |
980 |
82.5 |
350WQR1200-18-90 |
350 |
1200 |
18 |
90 |
980 |
83.1 |
350WQR1100-28-132 |
350 |
1100 |
28 |
132 |
740 |
83.2 |
350WQR1000-36-160 |
350 |
1000 |
36 |
160 |
740 |
78.5 |
350WQR1500-10-75 |
400 |
1500 |
10 |
75 |
980 |
82.1 |
400WQR2000-15-132 |
400 |
2000 |
15 |
132 |
740 |
85.5 |
400WQR1700-22-160 |
400 |
1700 |
22 |
160 |
740 |
82.1 |
400WQR1500-26-160 |
400 |
1500 |
26 |
160 |
740 |
83.5 |
400WQR1700-30-200 |
400 |
1700 |
30 |
200 |
740 |
83.5 |
400WQR1800-32-250 |
400 |
1800 |
32 |
250 |
740 |
82.1 |
High temperature resistant and non clogging submersible sewage pump usage:
1. The discharge of severely polluted wastewater from factories and businesses.
2. Urban sewage treatment plant drainage system.
3. Sewage drainage stations in residential areas.
4. Civil air defense system drainage station.
5. Wastewater discharge from hospitals and hotels.
6. Municipal engineering and construction sites.
7. Exploration and mining supporting equipment.
8. Rural biogas digesters for farmland irrigation.
9. The water supply system of a water plant.

Used for sewage discharge in municipal engineering, factories, commercial areas, hospitals, hotels, residential areas, etc.
Installation of hot water submersible sewage pump:

Fault analysis of large displacement submersible pump:
| Fault phenomenon | Root cause analysis | Mixing method |
| Insufficient flow or no water output |
1. Impeller rotation error 2. Whether the valve is open and intact 3. The impeller of the pipeline is blocked 4. Low speed 5. High head 6. The density of the pumping medium is relatively high 7. High viscosity of the medium 8. Damaged sealing ring (at the mouth ring) |
1. Adjust the rotation direction of the impeller 2. Inspection, maintenance, and elimination 3. Clean up debris 4. Check electrical equipment and circuits 5. Change the pump or reduce the head 6. Dilute with water to reduce concentration 7. Reduce viscosity 8. Replacement |
| Unstable operation |
1. Unbalanced impeller 2. Bearing damage |
1. Send to the manufacturer for replacement or calibration 2. Replace |
| The pump cannot start |
1. Lack of phase 2. Impeller stuck 3. Winding, connector or cable open circuit 4. The stator winding is burnt out 5. Electrical control malfunction |
1. Check and repair the circuit 2. Remove debris 3. Use an ohmmeter to check and repair 4. Repair and replace the winding 5. Repair or replace |
| excessive current |
1. Low working voltage 2. Pipeline and impeller are blocked 3. The height or viscosity of the liquid being pumped is relatively high 4. Use a low head |
1. Adjust the working voltage 2. Clean up blockages in pipelines and impellers 3. Change density or viscosity 4. Reduce traffic Increase head |
| Low insulation electrical group |
Leakage at the power supply terminal of 1 cable 2. Cable damage 3. Mechanical seal wear leads to leakage 4. Failure of each O-ring seal 5. The casing is corroded by the medium and leaks water |
1. Tighten and compress the mother tightly 2. Replace 3. Replace 4. Replace 5. Repair |