E-mail
2179629483@qq.com
-
Phone
15618637748
-
Address
No. 2 Base, 466 Xintang Road, Zhelin Town, Fengxian District, Shanghai
Shuoxiang Valve (Shanghai) Co., Ltd
2179629483@qq.com
15618637748
No. 2 Base, 466 Xintang Road, Zhelin Town, Fengxian District, Shanghai
Liquid nitrogen valves, nitrogen supply valves, and micro pressure regulating valves produced by ShuoxiangA comprehensive introduction covering product overview, functional features, usage instructions, and maintenance, suitable for industrial, medical, laboratory, and other fields:
Valve Type |
main purpose |
Typical application scenarios |
|---|---|---|
Liquid nitrogen valve |
Control the flow, cut-off, and regulation of liquid nitrogen (-196 ℃) |
Air separation equipment, low-temperature storage tanks, cold chain logistics, scientific research experiments |
Nitrogen supply valve |
Control the transportation, pressure regulation, and switching of gaseous nitrogen |
Industrial nitrogen production system, pipeline nitrogen supply, pneumatic equipment, protective gas system |
Micro pressure regulating valve |
Accurately control small pressures (such as 0~100Pa) |
Laboratory reactor, atmosphere control, ventilation system, precision instruments |
Ultra low temperature adaptabilityUsing low-temperature materials such as stainless steel and copper alloy to avoid cold brittleness.
Special sealing designUsing sealing structures such as polytetrafluoroethylene (PTFE) and metal bellows to prevent low-temperature leakage.
Anti icing designExtend the valve stem and provide insulation treatment to reduce operational failures caused by external icing.
Quick opening and closingCommonly used for emergency shutdown, compact structure, and rapid response.
high voltage resistantUsually, the design pressure is ≥ 1.6MPa, and high-pressure models can reach over 10MPa.
high sealing performanceSoft seal (rubber/PTFE) or metal hard seal to ensure zero nitrogen leakage.
Flow regulation functionSome models come with adjustment mechanisms that can stably output pressure.
Strong compatibilitySuitable for pure nitrogen, high-purity nitrogen, and mixed gases.
high-precision controlSensitivity can reach ± 1Pa, used for precision pressure regulation.
Voltage stabilization characteristicsAutomatically compensate for pressure fluctuations and maintain stable set values.
Small traffic designSuitable for low flow gas micro pressure control.
Lightweight structureCommonly used brass and stainless steel materials, with small interface sizes (such as 1/8 '~1/4').
Confirm that the valve material and pressure/temperature rating meet the system requirements.
Check the cleanliness of the pipeline to avoid damage to the sealing surface caused by welding slag and impurities.
Pre cooling is required during the installation of liquid nitrogen valves to avoid rapid cooling shock.
Valve Type |
Operation precautions |
|---|---|
Liquid nitrogen valve |
1. Slowly open to avoid sudden pressure rise caused by liquid nitrogen vaporization |
Nitrogen supply valve |
1. Gradually rotate the handwheel when adjusting pressure to avoid flow shock |
Micro pressure regulating valve |
1. First open the front valve, then slowly adjust the target pressure |
The liquid nitrogen system needs to be equipped with a safety relief device to prevent overpressure.
Nitrogen environment may cause hypoxia, and the operating area needs ventilation.
Micro pressure valves should be used to avoid overload and prevent accuracy failure.
Check the valve for external leakage, icing (liquid nitrogen valve), and abnormal noise.
Confirm the flexibility of the adjustment mechanism and whether there is any jamming.
Record pressure/flow data and monitor performance changes.
period |
Maintenance content |
|---|---|
monthly |
Clean the exterior of the valve body and check for loose fasteners |
biannually |
Check the wear of seals (such as valve seats, valve cores, O-rings) |
every year |
Comprehensive disassembly and inspection, replacement of vulnerable parts, calibration of micro pressure valve accuracy |
Fault phenomenon |
Possible reasons |
Handling suggestions |
|---|---|---|
Leakage of liquid nitrogen valve |
Seal aging, valve body freezing and cracking |
Replace the low-temperature seal, repair welding or replace the valve body |
Unstable pressure of nitrogen supply valve |
Valve core blockage, spring failure |
Clean the valve core, replace the spring or adjust the component |
Micro pressure valve cannot be adjusted |
Damaged membrane and blocked air path |
Replace the membrane and blow the pipeline with clean gas |
Regular sealing kit (gasket, O-ring, valve seat).
It is recommended to reserve corrugated pipe sealing components for liquid nitrogen valves.
Micro pressure valves require spare diaphragms and calibration tools.
Liquid nitrogen valvePriority should be given to long necked and vacuum insulated structures, with the recommended material being SS316L.
Nitrogen supply valveAccording to pressure selection, EP grade clean treatment valves are used for high-purity systems.
Micro pressure regulating valvePay attention to sensitivity and repeatability accuracy, and choose the live signal feedback model.